Electro-Voice F.01U.354.255 RE3-HHT765L UHF Wireless Transmitter with ND 76 Cardioid Capsule 488 to 524 MHz

User Manual - Page 73

For F.01U.354.255.

PDF File Manual, 82 pages, Read Online | Download pdf file

F.01U.354.255 photo
Loading ...
Loading ...
Loading ...
RE3
UHF Wireless Techni cal data | en 73
Electro
-Voice Installation manual 2021.06 | 03 | F.01U.362.808
Threaded Coupling:
1.25” Diameter
28 UN-2A Thread Pitch
Finish:
Black polyurethane paint
Materials:
Aluminum, steel, steel wire grille screen
Dimensions, Length:
Diameter:
3.6 in (91 mm)
2.0 in (50.5 mm)
ND86-RC3 dynamic supercardioid microphone head
Element Type:
Dynamic neodymium magnet structure
Frequency response, Close:
30 Hz 17 kHz
Frequency response, Far:
70 Hz 17 kHz
Polar Pattern:
Supercardioid
Sensitivity, Open Circuit
Voltage @ 1 kHz:
5.6 mV/Pascal
(-45 dBV/Pa)
Maximum SPL:
134.5 dB SPL (1% THD)
Power Requirements:
4-8 VDC
Polarity:
Positive pressure on diaphragm produces positive
voltage at center contact relative to ground contact
Electrical Contact:
3-Ring / 3-Pin
Threaded Coupling:
1.25” Diameter
28 UN-2A Thread Pitch
Finish:
Black polyurethane paint
Materials:
Aluminum, steel, steel wire grille screen
Dimensions, Length:
Diameter:
3.6 in (91 mm)
2.0 in (50.5 mm)
ND96-RC3 dynamic supercardioid microphone head
Element Type:
Dynamic neodymium magnet structure
Frequency response, Close:
30 Hz 15 kHz
Frequency response, Far:
140 Hz 15 kHz
Polar Pattern:
Supercardioid
Sensitivity, Open Circuit
Voltage @ 1 kHz in flat position:
4.7 mV/Pascal
(-46.5 dBV/Pa)
Loading ...
Loading ...
Loading ...