Oscilloscope Operations Screen Layout and Operations
123
Button Name Description
Save
Tapping this button opens a submenu, on which displays
5 options allowing you to save, record and plays back
the waveform data.
Tap
Save current page
to take a screenshot
image.
Tap
Record data
to save the current waveform
data.
Tap
Save Ref
to save a
copy of an existing
signal waveform
as reference.
Tap
Review data
allows selecting and reviewing
the previously stored waveform recordings.
Tap
Recall Ref
to retrieve the saved reference
waveforms.
All saved images are stored in the Data Manager
application for later reviews. See
Data Manager
Operations
on page 84.
Help
Provides instructions or tips for operations of various
functions.
Scope
Icon
Indicates the scope connection status. Tapping the icon
allows to reset the USB connection when
communication with the Scope Module fails. See 16.5
Troubleshooting
on page 129 for more information.
Math Channel
A math channel is virtual channel generated by mathematical function of the
input channel. It can be displayed in a scope in the same way as an input
signal, and like an input signal it has its own measure axis, scaling and color.
The MaxiScope module has a set of built-in math channels for the most
important functions, including “A+B” (the sum of channels A and B) and “A-B”
(the difference between channels A and B).
To use a math channel:
1. Tap the Tool button in the Top Menu.
2. Tap the Select a Math Channel option on the left column.
3. Tap the desired option on the right column to enable the math
channel in the channel list.
4. The Math Channel displays on the MaxiScope screen.