Main Feature Description
DS O5000 Series Digital Storage Oscilloscope User Manual
9
Chapter
Chapter
Chapter
Chapter 4
4
4
4 Main
Main
Main
Main Feature
Feature
Feature
Feature Description
Description
Description
Description
This chapter provides some general information that you need to learn before us ing an
oscilloscope. It contains :
1 . Oscilloscope setup
2 . Trigger
3 . Data acquisition
4 . Waveform scaling and positioning
5 . Waveform measurement
4.1
4.1
4.1
4.1 Oscilloscope
Oscilloscope
Oscilloscope
Oscilloscope Setup
Setup
Setup
Setup
While operating the oscilloscope, you may often use three features: Autoset, saving a setup and
recalling a setup. Hereinafter they are introduced one by one.
Autoset:
Autoset:
Autoset:
Autoset: This function can be used to adjust the horizontal and vertical scales of the oscilloscope
automatically and set the trigger coupling, type, position, slope, level and mode, etc., to acquire a
stable waveform display.
Saving
Saving
Saving
Saving a
a
a
a Setup:
Setup:
Setup:
Setup: By default, the oscilloscope will save the setup each time before being closed,
and automatically recall the setup once being turned on.
(Note:
(Note:
(Note:
(Note: If
If
If
If you
you
you
you modify
modify
modify
modify the
the
the
the setup,
setup,
setup,
setup, please
please
please
please
wait
wait
wait
wait for
for
for
for more
more
more
more than
than
than
than 5
5
5
5 seconds
seconds
seconds
seconds before
before
before
before turning
turning
turning
turning off
off
off
off the
the
the
the oscilloscope
oscilloscope
oscilloscope
oscilloscope to
to
to
to ensure
ensure
ensure
ensure the
the
the
the proper
proper
proper
proper
storage
storage
storage
storage of
of
of
of new
new
new
new settings.)
settings.)
settings.)
settings.)
You
can save 10 settings permanently in the oscilloscope and reset
them as necessary.
Recalling
Recalling
Recalling
Recalling a
a
a
a Setup:
Setup:
Setup:
Setup: The oscilloscope can recall any of your saved setups or the default factory
setup.
Default
Default
Default
Default Setup:
Setup:
Setup:
Setup: The oscilloscope is preset for normal operations when it is shipped from the
factory. This is the default setup. You may recall this setup at any time for your requirements. To
view the default settings, refer to Section 5. 6 .3 .
4.2
4.2
4.2
4.2 Trigger
Trigger
Trigger
Trigger
The trigger determines when the oscilloscope begins to acquire data and display a waveform.
Once a trigger is properly set up, the oscilloscope can convert unstable displays or blank screens
to meaningful waveforms. Here introduce some basic concepts about trigger.
Trigger
Trigger
Trigger
Trigger Source:
Source:
Source:
Source: The trigger can be generated with multiple sources. The most common one is the
input channel (alternative between CH1 and CH2). Whether the input signal is displayed or not, it
can trigger normal operation s . Also the trigger source can be any signal connected to an external
trigger channel or the AC power line (only for Edge triggers). Th e source with the AC power line