STEP 1 REMOVE PACKAGING (Cont.)
Ŷ Remove front access cover from unit by removing
two 1/4” hex head screws (some models have access
cover in a box on the left side of the cabinet). Place the
cover and screws to the side for future installation.
Ŷ Remove three 3/8” drive screws and two 7/16” drive
screws from each side of the unit to release it from
the shipping skid. Tip the unit from the side enough to
remove the shipping material from under the unit, but
above the shipping skid (both sides)
Ŷ CAREFULLY roll the unit off the back side of the ship-
ping skid.
Ŷ Handle from side only with a hand truck.
STEP 2 INSTALL WATER LINE
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line
of water.
ŶInstall a shut-off valve between the water valve and
cold water pipe in a basement or cabinet. The shut-
off valve should be located where it will be easily
accessible.
ŶTurn on the main water supply and flush debris. Run
about a quart of water through the tubing into a bucket.
Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in many
water supply kits. Before purchasing, make sure a saddle
type valve complies with your local plumbing codes.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed plumber.
Ŷ Route 1/4” OD copper or SmartConnect
(WX08X10006) plastic tubing between house cold
water line and the water connection location at the
front of the unit.
SmartConnect
Refrigerator
Tubing Kits are available. One 8’
(2.4m) water line (WX08X10006)
is needed for each unit. The
waterline will be taped to the
floor using masking tape after
anti-tip bracket installation.
Ŷ Tubing should be long enough to extend to the front of
the unit. Allow enough tubing to accommodate bend
leading into the water line connection. Unit must be
tipped on its side to route waterline underneath and to
the front of the appliance.
NOTE: The only GE Appliances approved plastic tubing
is supplied in the SmartConnect
Refrigerator Tubing
kits. Do not use any other plastic water supply line
because the line is under pressure at all times. Other
types of plastic may crack or rupture with age and cause
water damage to your home.
Shipping
Bracket
Access
Cover
7/16” Drive
Screws
1/4” Hex Head
Screws
3/8” Drive
Screws
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO
NOT drill into the refrigerator.
AVERTISSEMENT
Raccordez l’appareil à
une alimentation d’eau potable seulement. Une
alimentation d’eau froide est requise pour faire
fonctionner la machine à glaçons et le pichet à
remplissage automatique. La pression d’eau doit se
situer entre 40 et 120 psi. (275 à 827 kPa).
AVERTISSEMENT
RISQUE DE DÉCHARGE
ÉLECTRIQUE
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Realice la conexión a un
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento de la
máquina de hielos automática y de la jarra de llenado
automático. La presión del agua deberá estar entre 40
y 120 p.s.i. (275 – 827 kPa).
ADVERTENCIA
PELIGRO DE DESCARGA
ELÉCTRICA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.