TEC_TM_009 | REV. G | EN 07/19/2022 Page 17 of 76TR-30/36 INSTALL MANUAL
PAGE TITLE
ELECTRICAL AREA
WATER AREA
SITE PREPARATION
FIG. 1.
Water line connection. Fitting included, PEX not included
Plumbing Requirements
Water Supply
1/4" PEX tubing (1/4" O.D. lines
and fittings not included
NOTE: Copper line is not
recommended
Flow Rate 0.5 gpm / 1.89 lpm
Operating Pressure 30-100 psi (207-689 kPa)
Incoming Water Temperature 33-10 0°F (0.6-38°C)
NOTE: DIMENSIONS MAY VARY BY ± 1/8” (3.175 mm)
OPTIONAL ICEMAKER REQUIREMENTS
(TR-30FRZ/36FRZ-IM-C)
WATER SUPPLY REQUIREMENTS
Units with optional ice makers come with 20” (508
mm) of polyethylene tubing with a 1/4” O.D. push
connector for customer attachment.
Before installing your unit, prepare the water supply
line. Please see plumbing requirements in the
plumbing requirements table.
Purge the water line prior to final connection to the
unit. This removes any debris present in the line.
Only connect to a potable water supply!
Do not connect to a hot water supply!
Install the water filter before turning on the
water supply to the icemaker. See “Water Filter
Installation” (page 18).
A copper line is not recommended for this
application.
Check all water line fittings for leaks.
Tape the supply line to the floor before moving the
unit into its final installation location.
In the water connection area (see the rough opening
illustration), tape the water line to the floor.