NOTE! Propane regulator hose not included.
Gas Hook-Up Instrucons
WARNING! This grill is designed for non-combusble enclosures only, and must be installed and
serviced by a qualied installer to local codes.
WARNING! Cabinet frame, cabinet, and counter top must be made from non-combusble material.
WARNING! As indicated on the rang plate, this gas grill is designed to operate with gas supply
pressures of 11” WC for Propane and 7” WC for Natural Gas. For installaons where the gas supply
pressure exceeds these requirements, a regulator must be installed upstream of the grill’s components.
If the gas supply pressure is lower than these requirements, the unit will be under-red and will not
reach the maximum temperatures. Ensure that the supply line size complies with local and/or naonal
installaon codes.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instrucons. A exible metal connector is included to
simplify the installaon of the unit. Connect this exible metal connector to the are ng on the end of
the manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does
not pass through a wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to
connect the unit except to connect the cylinder regulator to the piping system. It must be connected with
!
!
General Informaon
This Gas Barbecue is cered under Canadian and American Naonal Standards, CSA 1.6-2018 and ANSI
Z21.58-2018 respecvely for Outdoor Gas Grills and should be installed to conform according to local
codes. In absence of local codes, install to the current CAN B149.1 Natural Gas and Propane Installaon
Code in Canada or to the Naonal Fuel Gas Code, ANSI Z223.1 in the United States.
If a rosserie motor is used, it must be electrically grounded in accordance with local codes or, in absence
of local codes, with the current CSA C22.1 Canadian Electrical Code in Canada or the Naonal Electrical
Code, ANSI/NFPA 70 in the United States.
WARNING: This product can expose you to chemicals including lead and lead compounds, which are
known to the State of California to cause cancer, and chemicals including di-n-butyl phthalate, which are
known to the State of California to cause birth defects or other reproducve harm. For more informaon
go to www.P65Warnings.ca.gov.
Propane Cylinder Specicaons
WARNING! If these instrucons are not followed exactly, a re causing death or serious injury may
occur.
WARNING! Do not store a spare propane cylinder on the shelf beneath the barbecue.
If the gas grill is being supplied with propane from a portable cylinder, a regulator specied by the manu-
facturer must be used. The regulator must supply a pressure of 11 inches water column (0.39 PSI) to the
gas grill and have a QCC1 type ng. Cylinders to be used with this unit must be supplied with a QCC1
cylinder valve. A QCC1 cylinder has a posive seang connecon, which will not allow gas ow unl a
posive seal has been achieved. It is also equipped with an excess ow device. In order to aain full ow
to the grill, the valves must be in the o posion when the cylinder valve is turned on.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a
cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance
with the specicaons for LP-gas cylinders of the Naonal Standard of Canada, CAN/CSA-b339, Cylinders,
Spheres and Tubes for Transportaon of Dangerous Goods; and Commission, as applicable or the Speci-
caons for LP-Gas Cylinders of the U.S. Department of Transportaon (D.O.T.). Cart models have been
designed for use with a 20 lb (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connecon device compable with the connecon
for outdoor cooking appliances. The propane cylinder must be provided with a shut-o valve terminat-
ing in a propane cylinder valve type QCC1, and a safety relief device having direct communicaon with
the vapor space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and
the cylinder shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD
(overll protecon device). Do not store a spare LP-gas cylinder under or near this appliance. Never ll the
cylinder beyond 80 percent full. If the preceding informaon is not followed exactly, a re causing death