STARTING AND STOPPING
English 17
Before starting
Water connector
Connect the water hose to the water supply (A). The
water flow is regulated using the water tap (B).
Residual-current device
(not for UK and Ireland 110V)
Make sure the ground fault circuit interrupter is
switched on. The LED indicates that the ground fault
circuit interrupter is on and that the machine can be
switched on. If the LED is not on, push the RESET
button (green).
Check the ground fault circuit interrupter. See
instructions under the heading Checking, maintaining
and servicing the machine’s safety equipment.
Starting
Grip the front handle with the left hand.
Grip the rear handle with your right hand.
Press in the power switch lock with your right-hand
thumb and press in the power switch.
Run the machine unloaded and in a safe manner for
at least 30 seconds.
Stopping
Stop the motor by releasing the power switch.
!
WARNING! Note the following before
starting:
The machine should be connected to an
earthed outlet socket.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Make sure you have a secure footing and
that the cutting blade cannot touch
anything.
Keep people and animals well away from
the working area.
!
WARNING! The machine (UK and Ireland
110V) is not equipped with a ground fault
circuit interrupter. The machine must
always be used with an isolating
transformer for protection in case an
electrical fault should occur.
!
WARNING! Never use the tool without the
ground fault circuit interrupter delivered
with the tool. Carelessness can result in
serious personal injury or even death.
!
WARNING! Make sure that the cutting
blade can rotate freely until it completely
stops. Carelessness can cause serious
personal injury.