SECTION 5 SERVICE TECH. INFORMATION
5E. WATER FLOW THROUGH THE SOFTENER VALVE
FAST RINSE CYCLE
ROTOR & DISC
POSITION SWITCH
OUTLET
DRAIN
POSITION
INLET
TOP
, 4,''/ DISTRIBUTOR _@
'% BOTTOM
DISTRIBUTOR
During D\ST RINSE, the rotor & disc is positioned so water flow ente_ts the resin tank
through the top distributor, and exits through the bottom distributor, to the drain.
The solid state timer again energizes the motor to return the valve to service, and as the
valve rotates, the position swit(h lever drops to ()pen the circuit. The wdve remains posi-
tioned in servi(e until the timer initiates the next regeneration.