SECTION 5 SERVICE TECH. INFORMATION
L J
5B. REGENERATION CYCLE TIMES
SEE REGENERATION TABLE ON PAGE 20, AND SPECIFICATIONS, PAGE 21.
CYCLE FLOW RATES (GALLONS PER MINUTE)
FILL (flow to salt storage tank) 0.1 (1.1 liters)
BRINING _ .16 (.6 liters)
BRINE RINSE t .11 (.4 liters)
BACKWASH (flow to drain) 1.8 (6.8 liters)
FAST RINSE 1.8 (6.8 liters)
TO SET DOUBLE BACKWASH (Softener has a backwash and fast rinse cycle heft)re brining, and after brining, which is
beneficial on some kinds of iron bearing \_ater):
(SE B( TI'ONS [] (SET/CLEAR), and [] (PRESENT TIME AND DAY)
1. Press and bold [] ............... entire display comes on.
Press [] to display 3 dashes
Press [] to display dbl
Press [] to display 18:88
2. Press [] to return present tilne.
IAM I.O.L--I
s__ _ _ _"_ s_I
[ db=J
REPEAT ABOVE STEPS TO CANCEL I)O/;BLE BACKWASI t.
CYCLE SEQUENCE WITH DOUBLE BACKWASH: 1. Fill 2. Backwash 3. Fast Rinse 4. Brining/Brine Rinse 5. Back-
\_ash 6. Fast Rinse Return to Service
OTHER RECHARGE CYCLE TIME ADJUSTMENTS
Cycle times ira specifications are factor.v settings. I)o the following to check f()r correct cycle times.
NOTE: Relnoving froln electrical po\_er (varies fiom 6 to 15
hours) resets tiHler to fat:tory programming.
I)ISPLAY M[ST SIIOW TIME AND DAY
a. 1f3:12 does show, go to step 4. --_1 { 71
I
b. If other than 3:12 (3:00 to 3:30),
press [] until 3:12 shows.
1. Press an(1 bold [] ...entire (lisplav I_,_ IO.It"lIOI
comes on. I_-_a IU.J't,,]KJI
i SUMOrUWeTH FR SA I
2. Press [] ...2:08 SHOWS; ine;-liqiiqg _ OB I]
#2 cycle brinin{_ & t....-" ( _, hr. rinse) and
80 ininutes (8 x 10).
If 2:08 does show, g(}t(} step 3.
ao
b.
.
If other than 2:08 (2:00 to 2:15),
press [] until 2:08 sho\Ts.
Press [] ...3:12 sho\\s, meaning
#3 cycle (backwash) and 12 minutes.
2" 12
It.=
NOTE: Instead of prograHliP_ing a (louble backwash, a
lonoer_ ,sin{fie,_back\T ash is beneficial (}n some types. (}firon
\\ _tter.
14,o41
a. 1 4OSl
b. If other than 4:04 (4:00 to 4:30) '_ i_!.O1[_1
' I_c_ IO'O!lal
press [] until 4:04 shows. IsoMoruWErHFRSaI
Press [] ...4:04 sh(}ws; meaning
#4 cycle (fast rinse) an(1 4 minutes.
If 4:04 does show, go to step 5.
5. Press [] ...18:88 sho\'_s.
6. Press [] ...to rettun to present time an(] (lay.
TO SET MINUTE -- LENGTH OF FILL CYCLE (factory setting, 16 minutes)
(SE BI TTONS [] (RECItARGE TIME), [] (SET/CLEAR), and [] (PRESENT TIME AND I)A¥)
1. Press an(1 bold [] until FILL shows, then 16 (factory setting).
Press [] to set the desire(1 fill ininutes
(flom regenerati(}n table).
2. Press [] to return present tiH_e an(] (lay.