Cobra CP4 450mm Single Pan Gas Pasta Cooker

Installation And Operation Manual - Page 9

For CP4. Also, The document are for others Cobra models: CN4

PDF File Manual, 21 pages, Read Online | Download pdf file

CP4 photo
Loading ...
Loading ...
Loading ...
7
9. Verify the operating pressure remains correct.
10. Check the pilot flame size.
NOTE:
Water connection shall be installed in accordance
with local water regulations in force and the
applicable standard / code, e.g. EN 1717 in UK /
Ireland, PCA in Australia.
A cold water supply must be connected to water
inlet connection (R
1
/
2
" BSP), located 50mm from LH
side, 556mm from rear and 135mm from floor.
Water connection should be plumbed, in
accordance with National / Local Codes covering
installation.
Water inlet pressure must be as follows:-
Minimum water supply pressure 150 kPa (22 psi).
Maximum water supply pressure 550 kPa (80 psi).
Water is drained from appliance by means of a
valve located behind front control panel.
A waste water tundish must be fitted below the
appliance drain outlet. This should be a minimum of
127mm (5”) major diameter.
If required the drain outlet can be extended in
order to exit above the tundish. All drain piping
must be with materials suitable for conveying boiling
water.
Drain connection is R1" BSP drain / overflow.
The following commissioning checks must be carried
out before the Pasta / Noodle Cooker is handed
over for use, to ensure the unit operates correctly
and operator(s) understand the correct operating
procedure.
1. Before leaving new installation;
a. Check the following functions in accordance
with operating instructions specified in
‘Operation’ section of this manual.
Light the Pilot Burner.
Light the Main Burner.
b. Ensure that each operator has been
instructed in areas of correct lighting,
operation and shutdown procedures for the
appliance.
2. This manual must be kept by owner for future
reference and a record of Date of Purchase,
Date of Installation and Serial Number of Unit
recorded and kept with this manual. (These
details can be found on Rating Plate attached to
inner R/H side of front access door panel. Refer
to Figure 1 in 'Installation' section).
NOTE:
If for some reason, it is not possible to get the
appliance to operate correctly, shut Off the gas
supply and contact supplier of this unit.
Loading ...