Cobra CP4 450mm Single Pan Gas Pasta Cooker

Installation And Operation Manual - Page 6

For CP4. Also, The document are for others Cobra models: CN4

PDF File Manual, 21 pages, Read Online | Download pdf file

CP4 photo
Loading ...
Loading ...
Loading ...
4
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
- All Other Markets:
NOTE:
(*) Burner operating pressure is to be measured at Burner Operating Pressure test point on gas
control valve, with burner operating at 'High Flame' setting.
Operating pressure is ex-factory set and is not to be adjusted, apart from when converting between
gasses, if required.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
A cold water supply must be connected to water inlet connection (R
1
/
2
" BSP), located 50mm from LH
side, 556mm from rear and 135mm from floor. Water connection should be plumbed in, in
accordance with National / Local Codes covering installation.
Maximum water supply pressure 550 kPa (80psi).
Tank max capacity - 40ltrs of water.
Input Rating (N.H.G.C.)
47 MJ/hr 47 MJ/hr 46 MJ/hr
Supply Pressure
2.75 - 4.50 kPa 2.75 - 4.50 kPa 1.13 - 3.40 kPa
Burner Operating Pressure (*)
2.6 kPa 2.6 kPa 0.92 kPa
Gas Connection ¾” BSP Male
Input Rating (N.H.G.C.)
46 MJ/hr 47 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa
Gas Connection ¾” BSP Male
Nominal Reduced Nominal Reduced
Heat Input (nett) 12.0 kW 5.4 kW 12.5 kW 6.2 kW
Gas Rate 1.27 m
3
/hr 0.42 m
3
/hr 0.97 kg/hr 0.48 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
9.5 mbar 27.7 mbar
Gas Connection
3
/
4
” BSP Male
Input Rating (N.H.G.C.)
46 MJ/hr 47 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa
Gas Connection ¾” BSP Male