Cobra CP4 450mm Single Pan Gas Pasta Cooker

Installation And Operation Manual - Page 19

For CP4. Also, The document are for others Cobra models: CN4

PDF File Manual, 21 pages, Read Online | Download pdf file

CP4 photo
Loading ...
Loading ...
Loading ...
17
- All Other Markets:
(*) NOTE:
Measure burner operating pressure at upper test point (Burner Operating Pressure) on gas control
valve located behind control panel, this is to be carried out with burner operating at ‘High Flame’
setting. Operating pressure is ex-factory set, through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. Refer to the information in this
section for further details.
Main Burner Injectors
Ø 3.10mm Ø 1.80mm Ø 1.70mm
Pilot Burner Injectors
0.62 0.35 0.35
Low Fire Screw
Ø 1.55mm
2 turns out (c.c.w.)
Ø 1.55mm
Fully In (c.w.)
Ø 1.55mm
Fully In (c.w.)
High Fire Screw
Fully Out (c.c.w.) Fully Out (c.c.w.) Fully Out (c.c.w.)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.92 kPa 2.6 kPa 2.6 kPa
Gas Regulator Cap Screw
Loading ...
Loading ...