16
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
NOTE:
* Measure burner operating pressure manifold test point with both burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart
from when carrying out gas conversion. (Refer to ‘Gas Conversion’ information for details).
Main Burner Injectors
Ø 2.10mm Ø 1.30mm
Pilot Burner Injectors
0.35 0.23
Low Fire Adjustment
1 turn out (ccw) ½ turn out (ccw)
Burner Operating Pressure (*)
1.0 kPa (*) 2.5 kPa (*)
Main Burner Aeration Shutter
15mm Open 15mm Open
Gas Regulator Cap Screw
Main Burner Injectors
Ø 2.10mm Ø 1.30mm
Pilot Burner Injectors
0.35 0.23
Low Fire Adjustment
turns out (ccw) ½ turn out (ccw)
Burner Operating Pressure (*)
10 mbar (*) 26 mbar (*)
Main Burner Aeration Shutter
15mm Open 15mm Open
Gas Regulator Cap Screw
Main Burner Injectors
Ø 2.10mm Ø 1.30mm
Pilot Burner Injectors
0.35 0.23
Low Fire Adjustment
1 turn out (ccw) ½ turn out (ccw)
Burner Operating Pressure (*)
1.0 kPa (*) 2.5 kPa (*)
Main Burner Aeration Shutter
15mm Open 15mm Open
Gas Regulator Cap Screw