9
NOTE:
A Manual Isolation Valve must be fitted to the
individual appliance supply line.
4. Correctly locate the appliance into its final
operating position and using a spirit level, adjust
the legs so that the unit is level and at the
correct height.
5. Connect the gas supply to the appliance. A
suitable joining compound which resists the
breakdown action of LPG must be used on
every gas line connection, unless compression
fittings are used.
6. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
7. Check that the gas supply pressure is as shown in
the Specifications section, ‘Gas Supply
Requirements’ tables.
NOTE:
The supply pressure is to be measured at the
manifold test point.
8. Light the Main Burners. Refer to the 'Operations’
Section', ‘Using the Griddle’ / ‘Using the Toaster’.
9. Verify that the supply pressure is still correct.
10. Check that the Main Burner is alight and adjust
the low fire adjustment screw on the open
burner gas control valves to obtain the desired
flame size.
11. Check / adjust the main burner aeration gap.
This gap should be set to the dimensions shown
in the 'Gas Specification Tables' in ‘Part 6 - Gas
Conversion’, ‘Gas Specifications’ tables.
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
The following commissioning checks must be
carried out before the Gas Griddle Toaster is
handed over for use, to ensure that the unit
operates correctly and the operator(s) understand
the correct operating procedure.
1. Before leaving the new installation;
a. Check the following functions in accordance
with the operating instructions specified in
the “Operation” section of this manual.
Light the Pilot Burners.
Light the Main Burners.
Check the Low Fire Burner operation.
Check the High Fire Burner operation.
b. Ensure that each operator has been
instructed in the areas of correct lighting,
operation, and shutdown procedures for the
appliance.
2. This manual must be kept by the owner for future
reference and a record of Date of Purchase,
Date of Installation and Serial Number of Unit
recorded and kept with this manual. (These
details can be found on the Rating Plate
attached to the inner R/H side panel, beneath
the middle shelf.
NOTE:
If for some reason it is not possible to get the
appliance to operate correctly, shut off the gas
supply and contact the supplier of this appliance.