RATING PLATE
Conforms to ANS1 STD Z21.1-2018 Certified to CSA STD 1.1-2018
HOUSEHOLD COOKING APPLIANCE. FOR INDOOR USE ONLY.
Model: UGP-36CR Serial No:
En conformité avec ANS1 STD Z21.1b-2018 Certifiés CSA STD 1.1-2018
APPAREIL DE CUISSON DOMESTIQUE. POUR USAGE INTÉRIEUR SEULEMENT.
Modèle: UGP-36CR N
o
de série:
Email / courriel:
Uniqueappliances.com
2245 Wyecroft Road, Oakville, ON
Canada L6L 5L7
Toll-free / sans frais: 877-427-2266
Manufactured & certified by: / Fabriqué et certifié par:
File Number:
4002621
Burner NG LPG (BTU/H)
A 1.36*2+0.73 0.89*2+0.53 20000
B 1.57 1.0 12000
C 1.07 0.74 6000
D 1.36 0.9 9000
E 1.79 1.16 15000
F 1.36 0.9 9000
Broil 1.42 0.94 10000
Oven 2.13 1.4 22000
Type of Gas
Natural Gas LP Gas
F D B
E C
A
INPUT PRESSURE
OVEN
OVEN LIGHT
IGNITOR
OVEN FAN
NG 7inch
120V, 60HZ, 5.0 AMP
Top Burners Brûleurs Supérieurs
Triple Crown
Burner
Brûleur Triple
Couronne
120V, 60HZ, 0.2 AMP
120V, 60HZ, 3 AMP
120V, 60HZ, 0.53 AMP
5inch
LPG 11inch 10inch
OUTPUT PRESSURE
Brûleur GN GLP (BTU/H)
A 1.36*2+0.73 0.89*2+0.53 20000
B 1.57 1.0 12000
C 1.07 0.74 6000
D 1.36 0.9 9000
E 1.79 1.16 15000
F 1.36 0.9 9000
Griller 1.42 0.94 10000
Four 2.13 1.4 22000
Type de Gaz
Gaz Naturel GPL
F D B
E C
A
PRESSION D’ENTRÉE
FOUR
LUMIÈRE DU FOUR
ALLUMEUR
VENTILATEUR DU FOUR
GN 7po
120V, 60HZ, 5.0 AMP
120V, 60HZ, 0.2 AMP
120V, 60HZ, 3 AMP
120V, 60HZ, 0.53 AMP
5po
GPL 11po 10po
PRESSION DE SORTIE
Minimum distance from the sides of the range above the countertop to
flammable walls be at least 13 inches. The minimum horizontal distance is
18 inches between the appliance and flammable structure extending from
the cooking surface. The minimum vertical clearance between the
countertop surface and flammable structure above the appliance is 30
inches. The minimum horizontal distance between overhead cabinets
installed on either side of the appliance shall not be less than the nominal
width of the appliance. A floor supported unit requires no space between
adjacent flammable structures. Do not store or use a gasoline liquid
propane cylinder or other flammable vapours and liquids in the vicinity of
this appliance. The gas appliance pressure regulator must be set for the gas
with which the appliance is used with Natural gas. Only the gas for which
the appliance is shipped from the factory adjusted for use with Natural Gas.
You can find the orifices in the package with LP manual. Conversion orifices
are located in the LP package. Please follow the instructions in the package
with the gas conversion orifices. Each orifice shall be clearly identified for
the gas for which it is designed, and the orifice size shall be indicated on
the spud. Vented unit. See installation instructions. May be vented. If
vented, see installation instructions. The gas appliance pressure regulator
must be set for the gas with which the appliance is used.
La distance minimale à respecter à partir des côtés de la cuisinière
audessus du comptoir jusqu’aux parois latérales inflammables doit être
d’au moins 13 po (33cm). La distance horizontale minimale entre l’appareil
et la structure inflammable s’étendant depuis la surface de cuisson est de
18 po (45cm). Le dégagement vertical minimal entre la surface du comptoir
et la structure inflammable au-dessus de l’appareil est de 30po (76 cm).
La distance horizontale minimale entre les armoires supérieures installées
de chaque côté de l’appareil ne doit pas être inférieure à la largeur
nominale de l’appareil. Une unité posée sur le sol ne nécessite aucun
aspace entre les structures inflammables adjacentes. Ne pas entreposer ni
utiliser d’essence, de bonbonne de propane liquide ni d’autres liquides ou
vapeurs inflammables à proximité de cet appareil. Le régulateur de
pression du gaz de l’appareil doit être réglé selon le type de combustible
utilisé par l’appareil avec du gaz naturel. Seul le type de gaz utilisé par
l’appareil est identifié. L’appareil est réglé pour une utilisation avec du gaz
naturel lorsqu’il quitte l’usine. Les orifices se trouvent dans l’emballage
avec le guide de gaz liquide. Les orifices de conversion se situent dans
l’emballage de gaz liquide. Veuillez suivre les instructions fournies avec les
orifices de conversion de gaz. Chaque orifice doit être clairement identifié
en fonction du type de gaz utilisé et sa taille doit être indiquée sur la tête e
buse à filetage mâle. Ventilation de l’unité. Se référer aux consignes
d’installation. Peut être ventilé. Si ventilé, se referrer aux consignes
d’installation. Le régulateur de pression de l’appareil à gaz doit être réglé
pour le gaz avec lequel l’appareil est utilisé.