26
6. Reconnect Gas and Electrical Supply to Range
Leak testing of the appliance shall be conducted according to the installation
instructions provided with the range.
Checking for Manifold Gas Pressure
If it is necessary to check the manifold gas pressure, remove the burner cap, inner
ring, outer burner head and burner base of the right front top burner and connect a
manometer (water gauge) or other pressure test device to the burner orifice. Use a
rubber hose with inside diameter of approximately 1/4“ and hold the end of the tube
tight over the orifice.
Turn the gas valve on. For a more accurate pressure check, have at least two (2) other
top burners burning. Be sure that the gas supply (inlet) pressure is at least one inch
above the specified manifold pressure.
Do not use a flame to check for gas leaks
a. Disconnect the range and its individual shut-o valve from the gas supply piping
system during any pressure of that system at test pressures greater than 14” of
water column pressure (approximately 1/2“ psig)
b. The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-o valve during any pressure testing of the supply system
at test pressure equal to or less than 14” water column pressure
INSTRUCTIONS FOR CONVERTING RANGE TO OPERATE ON
LIQUEFIED PETROLEUM GAS
CAUTION
INPUT PRESSURE OUTPUT PRESSURE
NG
7inch 7inch
LPG
11inch 10inch