Installationoftherange.
Read theseinstructionscompletely and carefully.
SurfaceBurnerAY ShutterAdjustment
The approximate height of tile flmne at tile
high or flfll ON position is a distinct inner blue
cone of at least 3/4 inch. Turn valve knob
counterclockx_ise 90 o/o the fifll ONposition
and a({just air shutmr astollows:
] To (x)riect ayellowllatlle--hl(Tease size of air
shutter opening.
[] To correct a lifting, but distinct, blue flame--
Decrease size of air shutter opening.
3/4"
Lockscrew __
Airshutter_
Orifice--___ _
OvenBurnerAir ShutterAdjustment
Lockscrew
Orificecap,
Air shutter
The oven burner flame should be a clean, blue
flame with distinct inner cones approximately 1/2
inch long.A soft, lazy flame with indistinct cones
means too much gas or not enough air.A noisy
lifting flame means too much air.
ff adjustmentsarenecessary:
[] First loosen tile lock s(rew located at tile top
of tl_eair shutter, tllen rotate tile air shutter
to the correct setting, and retighten screw.
[] Oven burner flame can be checked as
follows (without burner baffle in place):
] To correct a yellow Haiile--lncrease size
of air shutter opening.
[] To correct a lifting, but distinct, blue
flame-Decrease size of air shutter
opening.
[] The air shutter should be set approximately
2/3 open ti)r natural gas, and approximately
fifll open on I_t_gas.
[] Tile oven burner air shutter a({iusmmnt is
tile same on ranges _dth a gas pilot or electric
ignition.
[] Repeat steps 1 through 3 fin the broil
burner, if equipped, to properly at!lust tile
broil burner flame.