Installationoftherange.
Read theseinstructionscompletely and carefully.
ConvertBurner Orifices and PressureRegulator(if necessary)
[] ConvertingBurnerOrificestoLPGas: SCPRegulator:
NAT
LPgas setting
28
Tighten the orifice hoods fin"tile sudace burners
and oven burner approximately two complete
turns to the closed position and a(!just top pilots,
ifequipped. The gas pressure regulator must be
converted/o the 12 gas setting so that it will
pr(Mde a pressure of 10 inches water column to
the xvmgemanitixld.
[] ConvertingBurnerOrifices toNaturalGas:
(onlyifrangehasbeenoperatedprewouslyonLPgas)
NAT gas setting
Uns(rew the orifice hoods fin all burners (top
and oven) approximately two complete turns,
until the flame on the burner does not increase in
length. A(!just the top pilots (if equipped). The
gas pressure regulator must be set to the natural
gas setting so that it will provide a pressure of 4
inches of water cohmm in the range manitold.
[] RegulatorConversion:
All ranges me equipped with a gas pressure
regulator tin controlling and m_fintaining a
uniform gas pressure in the gas manifold of the
range. The burner orifices me sized tin the gas
pressure delivered by the regulator supplied.
The pressure regulator must not be rem()xv(1.
To convert the regulator fiom one gas to another,
reter to the ti)llowing illusuafion that applies:
Harper-Wyman Regulator:
_ _ NAT
For a Harper-W}qnan regulator, remove converter
cap by inserting a coin into slot in top and
twisting. Turn cap over and re-install.
On the SCP regulator, unscrew the converter
using a b/8 x;Ten(h. Turn tlle (ap over and
reinstall.
NOTE."Whatyoureadontheconvertercaporplungerls
thetypeofgasforwhichtheregu/atorlsseLIfyoursreads
NAT,theregulatorissetfornaturalgas.If yoursreadsLP,
theregulatorissetforLR
Forproperoperation,themaximuminletpressure
totheregulatormustbenomorethan14inchesof
water columnpressure.Fox-(hecking the
regulator, the inlet pressure must be at least
1-inch of water cohHnn (3.4 KI'A) greamr than
the regulator ou/put setting. If the regulator is
set fin 4 inches of water column pressure, the
inlet pressure nmst be at least 5 inches. If the
regulator is set fi)r 10 inches, the inlet pressure
must be at least 11 inches.
The gas supply line to the range should be 1/2
indl or 3/4 indl pipe.
Forstandingpilotmodels,make the necessmy oven
pilot a(!jusUnent (see directions in the IfRange
HasStandingPilots--Light andAdjust Surface
Burner Pilots section). Also burner air shutter
a(!justlIlents illav be nexessmy on all models to
complele conversion (see the Surface BurnerAir
ShutterAdjustment section).