level. If a face in the actual scene is darker than the set reference, the device increases the
exposure level.
- Minimum Duration: The extra time the device keeps the face exposure level after the face
disappears in the scene.
- Face Filtering Time: Time interval between the camera detecting a face and taking a capture
action. If the detected face stays in the scene for less than the set filtering time, capture will
not be triggered. For example, if the face filtering time is set as 5 seconds, the camera will
capture the detected face if the face stays in the scene for 5 seconds.
Set Shield Region
The shield region allows you to set the specific region in which the set smart function rule is invalid.
Steps
1. Select Shield Region.
2. Click to draw shield area. Repeat this step above to set more shield regions.
3. Optional: Click to delete the drawn areas.
4. Click Save.
Face Counting
Face counting detection can remove duplicate faces and calculate the number of objects that enter or
exit a certain configured area.
For certain device models, you need to select Face Counting on VCA Resource page first.
Only certain camera models support this function.
Set Face Counting Detection Rule
After setting the face counting detection rules and algorithm parameters, the device captures targets
and triggers linkage actions automatically.
Steps
1. Go to Configuration → Face Counting → Rule.
2. Check Rule.
3. Enter the min. pupil distance in the text field, or click to draw the min. pupil distance. The distance
of the drawn pupil will be displayed on the box below the live view.
• Min. Pupil Distance: The min. pupil distance refers to the minimum square size composed by the area
between two pupils, and it is the basic standard for a camera to identify a target.
4. Enter the max. pupil distance in the text field, or click to draw the max. pupil distance.