Karcher 9.982-506.0 ID 130/22 INDUSTRIAL DEDUSTER

Original Operating Manual - Page 22

For 9.982-506.0.

PDF File Manual, 33 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Troubleshooting and fault elimination
22/33
8.2 Initial fault elimination measures
NOTICE
könne
All the errors mentioned in the table below may be eliminated by yourself. In case of major problems
or other failures please contact the customer service of Ringler immediately.
Tel. ++49-(0)7171-94888-0
Perform maintenance tasks in accordance with the description in the Maintenance/Servicing chapter
Interference
Possible cause
Remedy
Motor is not running
Mains connection line
is not plugged in.
Plug in plug.
Motor protection switch tripped
Switch on motor protection switch.
Pre-fuse defective
Replace 16 A slow-acting fuse
Cable break
Replace mains connection line
Extraction output too low
Filter cake too large
clean
Container overfilled
Replace dust/chip bag
Vacuum line
Container / raw air
space clogged
Check permeability, if
applicable,
remove contamination
Chip bag is sucked in
Check rubber seal of filter chamber
/ container and repair if required
Rotary direction incorrect
Reverse plug polarity
Filter cartridge clogged
Check cleaning process, replace cartridge
if required
Dust penetration in the
clean air area
Filter cartridge worn or damaged
Insert new filter cartridge at once!!!
Tight fit of the filter cartridge
no longer ensured
Tighten clamping screws
Seal of cleaning shaft/filter cartridge
defective
Replace seal
Increase of volume
Wrong rotating direction of the fan
Reverse polarity of CEE plug
Component(s) have come loose
Check tight fit of all machine
parts
Loading ...
Loading ...
Loading ...