Operation
20/33
7.3 Emptying the collection container
The dust/chip bag in the container must be emptied when the maximum fill height is reached - see inspection
through the sight window - and always after daily use of the deduster. Chip and dust deposits to the upper
edge of the container's sight window mean: "Fill level for medium deposit" reached, best work operation no
longer ensured.
It is recommended to replace the dust/chip bag with a new one at once:
Fasten the two latchable running rollers of the deduster.
The two running rollers must not point inwards when shunting the container; otherwise, the container
cannot be moved properly.
The device must be switched off and the mains plug must be removed.
By pushing up the grip of the lifting and lowering device of the container (remains on top by the
latching device), the container is disconnected from the filter chamber and moved down to the bottom
with the lifting and lowering device.
The dust/chip bag must be closed carefully.
Removal of the dust/chip bag from the collection container may take place "on site" or at an internal
disposal point. Disposal must take place professionally and according to the local provisions!
When inserting a new dust/chip bag, ensure that it is smoothly applied to the walls of the container
and throwing as few folds at the upper edge as possible.
Push up the part of the dust/chip bag that protrudes over the container until the two container holders
and the rubber sealing sleeve (connection between vacuum line of the container and the filter
chamber/raw air side) are free.
Push the container to the holding device and carefully push down the grip of the lifting and lowering
device all the way.
The rubber seal at the upper edge of the container must be pushed against the filter chamber air-tight.
Then the RE 120 is ready again.
CAUTION
Generally observe that the air volume flow is not interrupted at a newly inserted dust/chip bag or a
dust/chip bag that has not collected any dust/chips yet, when switching on the deduster. This would
be the case, e.g. if the hose was completely clogged or if all pushers were closed at a branch or a Y-
piece. The consequence would be that the dust/chip bag would be sucked into the filter cartridge
through the large vacuum (Pmax at air volume flow 0 m/s) at once after activation.
If the empty filter bag is sucked into the filter cartridge (e.g. by the above situation), a new filter bag
must be inserted since it cannot be excluded that the dust/chip bag was damaged.