Loading ...
Loading ...
Loading ...
Accu-Steam™ Installation and Owners Manial
MP5004-1202 PAGE 13
INSTALLATION
TABLE TOP/STAND MODEL - EGF SERIES
LOCATION AND PLACEMENT
The AccuTemp ACCU-STEAM™ electric griddle has been designed to be placed on a
commercial kitchen counter-top, an AccuTemp griddle stand or directly onto any at, level
surface.
The operating temperature ranges from 200°- 400°F (93°- 204°C). Since these temperatures can
also be found on surfaces around the perimeter of the griddle, care should be given not to install
griddle next to or against, objects or surfaces with a low melting or ash point.
LEVELING
The griddle must be installed in a level condition. An out-of-level condition may cause uneven
temperatures and in server out of level condition damage to the griddle that may not be covered
by warranty. Use a spirit level resting on the griddle surface to ensure it is level front-to-back and
left-to-right.
Table Top
Install the (4) rubber foot tips provided with your griddle onto the four foot adjusters of each of
the griddle legs. This will keep the griddle from sliding on the counter-top under normal use.
Once the rubber foot tips have been installed, adjust the four foot adjusters up or down as needed
to level the griddle.
ACCUTEMP STAND
If on an AccuTemp™ stand with casters, ensure that the oor surface is level and place the
two locking casters to the “on” position and follow the leveling instructions to verify the the
appliance is level.
IN-FIELD MODIFICATIONS
This griddle has a totally unique design and is constructed unlike any other griddle on the market
today. Any modication may permanently damage the griddle.
Only a qualied service or electrician should complete the installation to ensure that all
eletrical and safety requirements are met and that all wiring is installed as per all National,
State and Local electrical codes.
WARNING
This appliance is heavy. For safe handling, the installer should obtain help as needed or
employ appropriate material handling equipment to remove the appliance from the skid
and move into the nal destination.
WARNING
Any in eld modications made without written authorization from AccuTemp™ will void
all warranties
NOTE
Loading ...
Loading ...
Loading ...