Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank, When the air
compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Pressure Release Valve: The
pressure release valve, located on the
side of the pressure switch, is
designed to automatically release
compressed air from the compressor
head and the outlet tube when the air
compressor reaches "out-out"
pressure or is shut off, Tr_epressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds, No
air should be heard leaking when the
motor is running, or continuous
leaking after unit reaches "out-out"
pressure,
Air Intake Filter (not shown) This
filter is designed to clean air coming
into the pump. Troisfilter must always
be clean and ventilation openings
free from obstructions, See
"Maintenance'.
How to Use Your Unit
How to Stop:
1, Set the 0n/Auto/0ff lever to
_,OFF_,.
Before Starting
Break*in Procedure
Risk of Unsafe
Operation. Serious
damage may result if the following
break*in instructions are not
closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been
replaced,
1, Make sure the On/Auto/Off lever
is in the "OFF" position.
2, Recheck all wiring, Make sure
wires are secure at all terminals
connections, Make sure all
contacts move freely and are not
obstructed,
3, Open the globe valve fully to
permit air to escape and prevent
air pressure build up in the air
tank during the braak-in period,
NOTE: The shut*off valve is net
supplied with this unit. You
must purchase the shut-off
valve separately.
4, Move the 0n/Auto/Off lever to
"0N/AUT0" position, The
compressor will start,