Electrolux ELTE7600AT 4.5 cu. ft. Stacked Washer and Electric Dryer Laundry Tower in Titanium, SmartBoost premixing Technology, Energy Star

Use and Care Manual - Page 28

For ELTE7600AT.

PDF File Manual, 78 pages, Read Online | Download pdf file

ELTE7600AT photo
Loading ...
Loading ...
Loading ...
28
Electrical Connection
(non-Canada) - 3 wire cord
1. Turn off power supply to outlet.
2. Remove the screw securing the
terminal block access cover in the
lower corner on the back of the
laundry center.
3. Install a UL-approved strain relief
according to the power cord/strain
relief manufacturers instructions in
the power cord entry hole below the
access panel. At this time, the strain
relief should be loosely in place.
4. Thread an UNPLUGGED, UL-approved,
30 amp. power cord, NEMA 10-30 type
SRDT, through the strain relief.
5. Attach the power cord neutral (center
wire) conductor to the SILVER colored
center terminal on the terminal block.
Tighten the screw securely.
6. Attach the remaining two power cord
outer conductors to the outer, BRASS
colored terminals on the terminal
block. Tighten both screws securely.
3-wire receptacle
(NEMA type 10-30R)
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before
servicing could result in personal injury or
even death.
Grounding Requirements -
Gas Dryer
1. The dryer is equipped with a three-
prong (grounding) plug for your
protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle.
2. The plug must be plugged into an
appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances. If
in doubt, call a licensed electrician.
3. DO NOT modify the plug provided with
this appliance. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
7. Follow manufacturer’s guidelines for
firmly securing the strain relief and
power cord.
8. Reinstall the terminal block cover.
IMPORTANT
If moving laundry center from a 4-wire
system and installing it in a 3-wire system,
move the internal ground from the center
terminal back to the GREEN screw next to
the terminal block.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp
wiring/conductor at connections.
1 2
1. Rubber washers must be present.
2. Use only new hoses.
INSTALLATION
Loading ...
Loading ...
Loading ...