Blue Seal Evolution GT60E Series 600mm Gas Fryer

Installation Operation Manual - Page 6

For GT60E.

PDF File Manual, 39 pages, Read Online | Download pdf file

GT60E photo
Loading ...
Loading ...
Loading ...
4
GT45E FAST FRIGAS FRYER (Single Tank - 20Ltr).
GT46E FAST FRIGAS FRYER (Twin Tank - 13Ltr per Tank).
GT60E FAST FRIGAS FRYER (Single Tank - 31Ltr).
- Australia:
- New Zealand:
- United Kingdom & EU (CE)
Category:
II
2H3P
(20. 37), II
2H3B/P
(20, 28-30),
Flue Type: A
1.
NOTE:
(
*
) Measure burner operating pressure at Lower Test Point (Out) on the gas control valve, with
both burners operating at 'High Flame' setting. Refer to Gas Conversion and Specification
Section for further details.
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure 1.13 - 2.00 kPa 2.75 - 3.00 kPa
Burner Operating Pressure (*) 0.98 kPa 2.50 kPa
Gas Connection ¾BSP Male
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure 1.13 - 2.00 kPa 2.75 - 3.00 kPa
Burner Operating Pressure (*) 0.98 kPa 2.50 kPa
Gas Connection ¾BSP Male
Heat Input (nett) 22.5 kW 22.5 kW 24.2 kW
Gas Rate 2.26 m
3
/hr 1.75 kg/hr 1.91 kg/hr
Supply Pressure 20 mbar 37 mbar 28-30 mbar
Burner Operating Pressure (*) 9.8 mbar 25 mbar
Gas Connection
3
/
4
BSP Male
Loading ...
Loading ...
Loading ...