Broan HRV 7.1 HEPA, The Healthy Solution

Installation Instructions and User Guide - Page 7

For HRV71. Also, The document are for others Broan models: EVO5 700 HRV HEPA, HRV 7.1 HEPA, EVO5 500 HRV, HRV 5.1

PDF File Manual, 24 pages, Read Online | Download pdf file

HRV71 photo
Loading ...
Loading ...
Loading ...
7
3. INSTALLATION
3.2 INSTALLATION KITS, TOOLS AND MATERIAL
The installation kit needed to perform most installations is IKSV1000 for Venmar units and IKSB1000 for Broan units.
Following are the tools and material needed:
• Measuring tape
Phillips no. 2 or Robertson no. 2 screwdriver
Small flat blade screwdriver (for wall control connection)
Wire stripper (for wall control connection)
Hammer and flat blade screwdriver (for plenum connection installation only, to make holes in existing metal duct)
Scissors or utility knife (to cut duct tape)
• Duct tape
Tin snips or metal shear (for plenum connection installation only, to cut ductwork)
Aluminum duct tape (for plenum connection installation only)
• Jig saw
Caulking gun and caulking.
3.4 PLANNING OF THE DUCTWORK
Keep it simple. Plan for a minimum of bends and joints.
Keep the length of insulated ducts to a minimum.
Do not ventilate crawl spaces or cold rooms. Do not attempt to recover the exhaust air from a dryer or a range hood. This
would cause clogging of the filters and recovery module.
If the house has two floors or more, be sure to plan for at least one exhaust register on the highest lived-in level.
3.3 LOCATING THE UNIT
Choose an appropriate location for the unit.
Within an area of the house where the ambient temperature is kept between 10°C (50°F) and 40°C (104°F)
Away from living areas (dining room, living room, bedroom), if possible
So as to provide easy access to the interior of the unit, for regular and annual maintenance
Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from the unit
Away from hot chimneys and other fire hazards
Allow for a power source (standard 3-prong grounding outlet)
Close to a drain. If no drain is close by, use a pail to collect run-off.
Hang the unit with the four hooks, chains and springs provided. See illustration at right.
VD0515
Make sure the unit is level.
CAUTION