Kolpak P8-1208-CT Walk-In Cooler & Top Mounted Compressor

Polar pak installation - Page 13

For P8-1208-CT.

PDF File Manual, 33 pages, Read Online | Download pdf file

P8-1208-CT photo
Loading ...
Loading ...
Loading ...
13
Electric Defrost Timer (Freezers)
Defrost Time Clock
The defrost timer clock must be set to the correct time at initial start-up and after any power interruptions.
Set the clock by rotating the clock face until the correct time is at the arrow on the face of the timer.
The switch is programmed by pushing the captive trippers to the inner ring for the entire period the load is to be
turned “ON”.
When a tripper is pushed to the outside, the switch is in the “DEFROST” position.
Each defrost tripper represents 15 minutes of defrost time.
The timer is factory set for four defrost cycles daily at the following times: 4:00AM, 10:00AM, 4:00PM, and
10:00PM. Each defrost cycle is programmed for 30 minutes duration.
The defrost times can be changed to initiate at periods of low activity.
A setting of two to four defrost cycles per day is typical. For heavier frost loads, additional cycles may be required.
The timer starts the defrost cycle automatically at the predetermined times.
NOTE: If the defrost termination thermostat fails to close, the fail safe setting on the timer will terminate the defrost cycle.
When the defrost cycle begins:
The compressor and evaporator fan motors will stop.
The evaporator coil heaters will activate and increase the coil temperatures above 32°F/0°C, melting the frost and ice.
NOTE: Walk-in temperatures will elevate above the set point during defrost cycles (30 minutes, 4 times per day)
but will return to the set point once the defrost cycle is complete.
When the defrost time is complete or the evaporator coil warms to approximately 55°F/13°C, the compressor will
start the refrigeration cycle but the evaporator fan(s) will remain idle until the evaporator coil temperature is at or
below freezing.
Once the evaporator coil temperature reaches approximately 30°F/-1°C, the evaporator fan(s) will activate.
The system operates in the refrigeration cycle until another defrost cycle is initiated by the timer.