Snapshots 259
Automation Safing Using the Channel Knob Module (CKM)
To Automation Safe a channel using the CKM:
1 Bank the desired channel to the faders.
2 Press the Select switch for the channel you want to Automation Safe so it lights, then press the INPUT Channel Control Func-
tion switch so it lights.
– or –
Touch the channel’s Input touch zone on the associated Channel Touch Module (CTM).
Input parameters are assigned to the associated CKM.
3 Locate the Automation Safe encoder, indicated by Auto Sf on the encoder display, and press the encoder.
The encoder In switch lights green, and the channel is Automation Safed.
CKM Channel Control Function Switches
Input touch zone on the CTM in Meters view (left) and in Channel view (right)
Automation Safe parameter on a CKM encoder
MIXMIXMIXPLUG-INSDYNAMICSEQINPUTCHANNEL