Whirlpool LTG6234DZ1 27 IN. (69 CM) GAS WASHER/DRYER

INSTALLATION INSTRUCTIONS - Page 6

For LTG6234DZ1. Also, The document are for others Whirlpool models: LTG6234D

PDF File Manual, 12 pages, Read Online | Download pdf file

LTG6234DZ1 photo
Loading ...
Loading ...
Loading ...
6
L.P. gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT:
The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
Gas Supply Line
½ in. IPS pipe is recommended
³⁄₈
in. approved tubing is acceptable for lengths under 20 ft
(6.1 m) if local codes and gas supplier permit.
Lengths over 20 ft (6.1 m) should use larger tubing.
Must include
¹⁄₈
in. NPT plugged tapping accessible for test
gauge connection, immediately upstream of the gas supply
connection to the dryer (see illustration).
Gas supply line coupling must be 34 in. (86.4 cm) to 37 in.
(94 cm) from the floor.
Must include a shutoff valve:
An individual shutoff valve must be installed within six (6) feet
(1.8 m) of the washer/dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54. The location should be
easy to reach for opening and closing.
If you are using natural gas, do not use copper tubing.
If your washer/dryer has been converted to use L.P. gas,
³⁄₈
in. L.P. compatible copper tubing can be used. If the total
length of the supply line is more than 20 ft (6.1 m), use larger
tubing.
NOTE:
Pipe-joint compounds that resist the action of L.P. gas
must be used. Do not use TEFLON
®†
tape.
Dryer Gas Connection
This washer/dryer is equipped with its own permanent,
flexible gas connector, design-certified by CSA International,
for connecting the washer/dryer to the gas supply line.
Flexible gas connector
Burner Input Requirements:
Elevations up to 10,000 feet (3,048 meters):
The design of this washer/dryer is certified by CSA
International for use at altitudes up to 10,000 ft (3,048 m)
above sea level at the B.T.U. rating indicated on the model/
serial number plate. Burner input adjustments are not required
when the dryer is operated up to this elevation.
Elevations above 10,000 feet (3,048 meters):
When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner B.T.U. rating shown on the model/serial number
plate is required for each 1,000 ft (305 m) increase in elevation.
Gas Supply Pressure Testing
The washer/dryer must be disconnected from the gas supply
piping system during any pressure testing.
Venting Requirements
WARNING:
To reduce the risk of fire, this washer/dryer
MUST BE EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories. For more
information, see the “Assistance or Service” section of your
“Washer/Dryer User Instructions.”
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.
1. Gas shutoff valve
2.
¹⁄₈
in.
NPT plugged tapping
3. ½ in. NPT gas supply line
4. Gas supply line coupling 34 in. (86.4 cm)
min. to 37 in. (94 cm) max. from floor
2
1
3
4
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.