4
A sturdy floor to support the washer/dryer weight (washer/
dryer, water and load) of 500 lbs (226.8 kg).
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire washer/dryer. Clothes may not tumble properly and
automatic sensor cycles may not operate correctly if dryer is
not level. Installing on carpet is not recommended.
A water heater set to deliver 120°F (49°C) water to the washer.
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of 5-100 psi
(34.5-689.6 kPa).
The washer/dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Do not operate your washer in temperatures below 32ºF (0ºC).
Some water can remain in the washer and can cause damage in
low temperatures. See “Washer/Dryer Care” in the “Washer/Dryer
User Instructions” for winterizing information.
Do not operate your dryer in temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the washer/dryer in garages, closets, mobile homes,
or sleeping quarters. Contact your local building inspector.
NOTE:
No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation Clearances
The location must be large enough to fully open the dryer door.
Washer/Dryer Dimensions
*Most installations require a minimum 5½ in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum installation spacing for recessed area or closet
installation
The following dimensions shown are for the minimum spacings
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Rear clearance may be 0 in. when house exhaust system is
lined up directly with dryer exhaust.
Mobile Home - Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your dealer.
Mobile Home Installation Kit Part Number 346764. See “Tools
and Parts” section for ordering information.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Drain System
The washer/dryer can be installed using the standpipe drain
system (floor or wall), the laundry tub drain system, or the floor
drain system. Select the drain hose installation method you need.
See “Alternate Parts.”
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of
2 in. (5 cm). The minimum carry-away capacity can be no less
than 17 gal. (64 L) per minute. A 2 in. (5 cm) diameter to 1 in.
(2.5 cm) diameter standpipe adapter kit is available. See
“Alternate Parts.”
The top of the standpipe must be at least 39 in. (99 cm) high and
no higher than 96 in. (2.4 m) from the bottom of the washer.
*
.
.
.
.
.
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents
.
.
.
.
.
.
24 in.
(155 cm )
48 in.
(310 cm )
2
2
2
2
(99 cm)
39
2
1
Loading ...
Loading ...