Configuration menu
www.bora.com
Menu item
C2
: speed of the cover flap motors
Setting Cover flap speed
0
100%
1
40%
2
46.7%
3
53.4%
4
60%
5
66.7%
6
73.3%
(Factory setting)
7
80%
8
86.7%
9
93.3%
Tab. 7.7 Speed of the cover ap motors
Menu item
C5
: manual operation of the cover flap
motors
Setting Function
0
Leave menu item
1
Opening the cover flap
2
Closing the cover flap
Tab. 7.8 Manual operation of the cover ap motors
i
If setting 1 or 2 is selected in menu item C5, the cover
flap can be manually opened or closed with a long press
on the touch surface of the control knob.
Menu item
C6
: switching fan PWM values
Setting Configuration
0
Fan PWM values
PKA3/PKA3AB
(Factory setting on
PKA3/PKA3AB)
1
Fan PWM values
PKAS3/ PKAS3AB
(Factory setting on
PKAS3/ PKAS3AB)
Tab. 7.9 Switching fan PWM values on PKA3/PKA3AB and
PKAS3/PKAS3AB
Menu item
C7
: installation of left cooktop 0°/180°
Setting Set-up
0
Standard installation
(0° installation)
(Factory setting)
1
Installation rotated by 180°
2
Not connected
Tab. 7.10 Set-up of the left cooktop
Menu item
C8
: installation of right cooktop 0°/180°
Setting Set-up
0
Standard installation
(0° installation)
(Factory setting)
1
Installation rotated by 180°
2
Not connected
Tab. 7.11 Set-up of the right cooktop
Menu item
C4
: operation with or without a wall
sleeve (only in exhaust air mode)
Prerequisite: The exhaust air mode setting was selected in menu
item
C3
.
Setting Wall sleeve
0
Operation without wall sleeve
1
Operation with wall sleeve
(Factory setting)
Tab. 7.3 Operation with or without a wall sleeve
i
If a wall sleeve is used in exhaust air mode, when
activating the cooktop extractor a higher power level is
automatically and temporarily activated so that the wall
sleeve opens properly (wall sleeve function).
Menu item
CA
: number of fans installed
i
If an additional fan is used when the system is installed, it
must be activated in the menu.
Setting Number of fans
1
One fan connected
(Factory setting)
2
Two fans connected
Tab. 7.4 Number of fans installed
7.3 Description of the other menu
items
Menu item
C0
: volume of the acoustic signals
Setting Acoustic signal volume
0
100%
(Factory setting)
1
10%
2
20%
3
30%
4
40%
5
50%
6
60%
7
70%
8
80%
9
90%
Tab. 7.5 Acoustic signal volume
Menu item
C1
: demo mode
i
In demo mode all control knob functions are available
and the electrical cover flap and fan are operative. The
cooktop heating function is deactivated. Demo mode is
used, for example, for exhibitions.
Setting Operating mode
0
Normal operation
(Factory setting)
1
Demo mode
Tab. 7.6 Normal operation or demo mode