Functions and operation
www.bora.com
i
If no suitable cookware is recognised (pan size
recognition) on either of the two cooking zones on the
induction cooktop PKFI3 within 10 seconds, the bridging
function is deactivated.
6.5.6 Pause function (system function)
With the pause function all cooking zones can be quickly and
easily deactivated temporarily. When the function is cancelled,
operation resumes at the original settings.
The cooking session can be paused for max. 10 minutes. If the
pause function is not deactivated in this time, all cooking zones
are switched off.
i
During the pause, fan function is not interrupted. Active
bridging and egg timer functions remain active. Active
timer functions are paused.
Activating the pause function
2x
1
2
Fig. 6.25 Activating the pause function
XX
Double tap the cooktop extractor control knob
XO
1 1
pulsates in the cooktop extractor control knob display.
XO
The cooktop control knob displays are dimmed.
Deactivating the pause function
2x
1
2
Fig. 6.26 Deactivating the pause function
XX
Double tap the cooktop extractor control knob
XO
The cooktop control knob displays light up again.
XO
Paused cooking zone timers resume their countdown.
6.5.5 Bridging function
(only on PKFI3 and PKT3)
With the bridging function two cooking zones can be combined
to form one large cooking zone. The power for the combined
zones is then adjusted using any control knob. Power
adjustment takes place simultaneously (both cooking zones are
operated on the same power level).
This means, for example, that on the surface induction cooktop
very large pans or roasters can be used.
XO
Both cooking zone indicators are activated in the display on
both control knobs.
i
If the bridging function is activated on cooktop PKFI3, the
power setting cannot be used. Use of the power setting is
possible on the Tepan stainless steel grill PKT3.
i
If both cooking zones are active when the bridging
function is activated, the higher of the two power levels
will be adopted for both cooking zones. Active additional
cooking zone functions will be adopted by the cooking
zone with the higher power level.
Activating the bridging function
1
+
2
Fig. 6.24 Setting cooking zone power levels
XX
Touch both control knobs at the same time
XO
An acoustic signal can be heard and the bridging function is
activated.
XO
The power level and both cooking zone indicators are shown
on both control knobs.
Deactivating the bridging function
XX
Set the power level
0
.
or
XX
touch command on both control knobs at the same time.
XO
An acoustic signal can be heard and the bridging function is
deactivated.
XO
All cooking zones are deactivated.
XO
Each cooking zone then goes back to being operated separately.