Installation
www.bora.com
5.5 Installing the cooktop
INFO Clearance of one millimetre should be planned
between the built-in appliances.
INFO A clearance of two millimetres should be
planned around the built-in appliances.
INFO A mounting rail should ideally be installed
between adjacent cooktops (PZMS mounting
rail available as an accessory).
INFO Alternatively, the cooktop can be installed
rotated by 180°.
5.5.1 Installing the control knob behind the
floor unit’s panel
INFO Pre-drill the bore holes to prevent tearing out
the panel.
Fig. 5.7 Installed control knobs and cooktop
≥70
Ø50 ±0,5
370
80-140
Fig. 5.8 Drilling diagram
[1] Cooktop
[2] Worktop
[3] Floor unit’s panel
5.4.2 Surface mounting
x
B ±2
≤ R5
≥ 74
≥ 74
516 ±2
≥ 700
Fig. 5.5 Cut-out dimensions surface mounting
12
10 - 40
Fig. 5.6 Surface mounting cut-out
Cut-out dimensions when installing cooktops or cooktops
and the cooktop extractor next to each other:
Cooktops/cooktop extractor B in mm
1/0 346
1/1 457
2/1 828
3/2 1310
4/2 1681
Tab. 5.3 Cut-out dimensions appliance combinations surface
mounting