12. Technical Data
This cooker is designed for use on Natural gas, although a
conversion for LP (
LPG X Propane (2.54 kPa)
) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia
Connection & Test Pressures
Gas (Rp ½ at rear right-hand side) Electric
Natural gas
1 kPa 230 V 50 Hz
Propane 2.54 kPa
See appliance data badge for test pressures.
Dimensions
Overall height minimum 900 mm maximum 925 mm
Overall width 1100 mm
Overall depth 600 mm (to fascia); 650 mm (over handles)
Minimum space above hotplate 650 mm
Refer to Positioning the Cooker’.
Ratings
Hotplate
Bypass
Screw*
Natural gas 1.0 kPa LP gas 2.54 kPa
Input Injector Input Injector
Wok burner 55
15.2 MJh
-1
internal 88
15.0 MJh
-1
internal 57
external 168 external 98
Large burner 41
12.3 MJh
-1
165 12.0 MJh
-1
89
Medium burners 33
6.2
MJh
-1
115 6.2 MJh
-1
67
Small burner 25
3.7 MJh
-1
92 3.3 MJh
-1
48
Gas burner inputs based on Gross Caloric Value.
* The valves in this range are fitted with adjustable bypass screws. The range is supplied with the bypass screws set for Natural
gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Left-hand Oven Right-hand Oven
Multi-function
Forced Air
Convection
Maximum power output @ 230 V 50 Hz 2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) AA
Energy consumption based on standard load
0.95 kWh 0.90 kWh
Usable volume (litres) 69 69
Size Large Large
Time to cook standard load 41 minutes 38 minutes
Surface area of the grid
1400 cm
2
1400 cm
2
Grill 2.3 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.4 kW.
Loading ...