INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
28
Electrical Connection
This appliance must be installed by a qualied electrician
to comply with with current AS/NZS 3000 Wiring Rules
and regulations in force.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the cooker data
plate.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
The cooker is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit breaker
that completely disconnects the appliance from the mains,
with a minimum contact break distance of 3 mm.
n
WARNING: THIS APPLIANCE MUST BE EARTHED.
The appliance must be connected to an ecient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations.
Earthing is a safety measure required by law, and must be
performed with particular care by a qualied technician,
who must also check that the electricity supply
characteristics are correct.
The total electrical load of the appliance is approximately
7.4 kW. The cable size used should be suitable for this load
and comply with all local requirements.
Please note the maximum cable sizes are 6 mm² for the screw
terminals and 10 mm² for the 3-pronged links.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 8.11 & Fig. 8.12).
Check that the links are correctly
tted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.
An isolation switch shall be provided and mounted near
the cooker, in a readily accessible position, in compliance
with AS/NZS 3000 and/or AS/NZS 5601 as applicable for the
appliance conguration.
Fixed Wiring
For connection to xed wiring, i.e. exible conduit, remove
the electrical terminal cover box on the back panel. Using the
two screws, x the strain relief bracket in position.
Fix the conduit-to-conduit mounting bracket onto the
strain relief bracket. Connect the mains cable to the correct
terminals for your electrical supply type (Fig. 8.13 & Fig. 8.14).
Check that the links are correctly tted and that the terminal
screws are tight.
ArtNo.132-0001 - 1 phase 240Vac 50Hz
1-phase 220-240 V
AC
50 Hz
ArtNo.132-0003 - Single-phase connections (AUS)
AN
ArtNo.132-0002 - 3 phase 240/415Vac 50Hz
3-phase 400 V
AC
50 Hz
ArtNo.132-0004 - Fixed wiring connection (AUS)
Mains
terminal
Fixing bracket for
conduit connection
Conduit
Cable clamp
Strain relief
bracket
Fig. 8.11
Fig. 8.12
Fig. 8.13
Fig. 8.14