16
preheat the grill for 10 minutes before placing food.
2.Controller Operation
Shutdown Cycle:
Auger turns off
Fan continues to run for 5 minutes
After you are finished cooking, turn the Temperature Dial to Shutdown Cycle position. The
function of this setting is to leave the Draft Induction Fan running for 10 minutes to burn
redundant pellets in the fire pot. After the fan runs for 10 minutes, it will shutdown and the
controller will power off.
CAUTION: The main power switch will shut the power off to the controller. The Temperature
Dial Knob switch will cut off power to the grill components only. When servicing the controller
or any parts, ensure that the power supply is disconnected to avoid a shock hazard.
LEr(Low Temperature Alarm )
Grill temperature was below 150 for more than 20 minutes.
HEr(High Temperature Alarm )
Grill temperature reached 550.
Er1
Ensure temperature probe is properly connected to the controller board.
Er2
Temperature probe short circuit.
Whenever either of these alarm conditions occurs you should check to see
what caused this condition and fix the problem.
WARNING: After Shutdown Cycle has ran for 10 minutes, turn the Switch to the
OFF(O) position. Otherwise, it may cause a fire in the Firepot to go into the Pellet
Hopper.