LIGHTING GAS BURNERS FITTED WITH FLAME FAILURE SAFETY DEVICE
In order to light the burner, you must:
1. Turn the knob (gs. 8a - 8b) in anti-clockwise direction up to the maximum aperture
(symbol “
” ), push in and hold the knob; this will light the gas.
If there is no mains electrical supply, bring a lighted match close to the burner.
2. Wait for about ten seconds after the gas burner has been lit before letting go of the
knob (valve activation delay).
3. Adjust the gas valve to the desired position.
Important
If the burner ame should go out, the safety valve will automatically stop the gas ow
To re-light the burner, return the knob to closed “
position (burner o󰀨), wait for at
least 1 minute and then repeat the lighting procedure.
N.B. If your local gas supply makes it di󰀩cult to light the burner with the knob set to
maximum, set the knob to minimum and repeat the operation.
DUAL BURNER - MODELS DEGHBG90 ONLY
The Dual Burner is a very exible burner which allows di󰀨erent regulations and optimal
cooking.
It is composed by one inner and one outer crown: the inner and outer crown can be used
together or separately.
The Dual burner is controlled by two separate knobs (g. 9):
one knob for the inner crown only (“ ” symbol identifying the control knob)
;
one knob for the outer crown only (“
” symbol identifying the control knob).
The Dual burner can be used:
as a small burner (ame produced only by the inner crown);
as a Ultra-rapid burner (ame produced only by the outer crown);
as a high-power burner (all ames produced simultaneously by inner and outer crown).
IMPORTANT: After using the dual burner check both the control knobs
are in the closed “ ” position.