13
tighten or replace connections as appropriate.
Warning: Do not use any naked ame to check for leaks.
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropriate for
the gas type.
4. Turn on the appliance gas controls and light each burner. Check for a well dened
blue ame without any yellow tipping. If any abnormality is evident then check that the
burner ame spreader and burner cap/s are both located properly.
5. Check the minimum burner setting by quickly rotating the gas control knob from the
maximum to the minimum position, the ame must not go out. If adjustment is required
carry out the “MINIMUM BURNER SETTING ADJUSTMENT” procedure described
below.
6. If satisfactory performance cannot be obtained, the installer shall check the installation
and notify the local gas supply authority for a gas supply problem, or if it is an appliance
problem, our Customer Service Centre should be called to obtain the nearest
authorized Delonghi Service Agent.
7. Where the appliance data plate cannot be easily read with the appliance in the
installed position the duplicate data plate must be attached to adjacent surface and
the duplicate Natural gas / ULPG conversion label should also be included where a
Natural gas / ULPG conversion has been completed.
INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY
If this appliance has to be installed with a hose assembly, the installer shall refer to the
network operator or gas supplier for conrmation of the gas type, if in doubt.
When used with a exible hose, the connector on the wall should be between 800 mm
to 850 mm above the oor and in the region outside the width of the appliance to a
distance of 250 mm.
The supply connection point shall be accessible with the appliance installed.
Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certied.
The thread connection shall be Rp 1/2” (ISO 7-1) male.
IMPORTANT WARNING: After connection the installer must check that the hose is
not kinked, subjected to abrasion or permanently deformed. The installer must check
also that the hose is not near (or in contact) with any hot surfaces e.g. base of metal
hotplate, underbench oven etc.
The hose assembly shall be as short as practicable and comply with relevant
AS/NZS5601.1 requirements.
IMPORTANT WARNING: The installer shall ensure the hose assembly is restrained
from accidental contact with the ue outlet of an underbench oven.