12
GAS SUPPLY
This appliance is suitable for use
with Natural Gas or ULPG (Check
the “gas type” sticker attached to the
appliance).
For Natural Gas the gas supply must
be regulated to obtain a pressure of 1
kPa:
with the two semi-rapid (SR) burners
operating at the maximum - model
DEGHBG60 only;
with the triple-ring (TR) burner
operating at the maximum - model
DEGHBG70 only;
with the dual (DB) burner operating
at the maximum (inside and outside
ames in simultaneously at the
maximum) - model DEGHBG90
only.
For ULPG models connect the gas
supply directly to the appliance test
point adaptor (supplied with the
conversion kit) and ensure that the
supply pressure is regulated to 2.75
kPa.
Do NOT force the ”elbow“ rotation
prior to loosening nut.
Do NOT over tighten the nut at the
”elbow“.
1. After connecting the gas supply, check
the piping and connections for leaks
using a soap and water solution. The
presence of bubbles indicates a leak,
Gas connection for
NATURAL GAS
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
Gas connection for
ULPG
Test point adaptor
Gasket
Gas inlet pipe
Test
point
Brass conical adaptor
(Thread tight: use
suitable seal)
Figure 4a
Figure 4b
Figure 4c