TABLE FOR THE CHOICE OF THE INJECTORS
Natural Gas ULPG
Test Point Pressure [kPa] 1.0 2.75
BURNER
Injector
Orifice
Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice
Dia.
[mm]
Gas
Consumption
[MJ/h]
Auxiliary (AUX) 0.92 3.90 0.56 3.90
Semi-rapid (SR) 1.17 6.50 0.70 6.20
Rapid (R) (
1
) 1.54 11.75 0.88 10.78
Triple-ring compact (TRC) (
2
) 1.48 10.70 0.85 9.60
Triple-ring (TR) (
3
) 1.68 13.70 1.04 14.10
Dual (DB) - inner crown (
4
) 0.72 2.40 0.43 2.10
Dual (DB) - outer crown (
4
) 1.23 (x2) 13.80 0.66 (x2) 11.40
(
1
) Only for the models DEGHBG70, DEGHBG90
(
2
) Only for the model DEGHBG60
(
3
) Only for the model DEGHBG70
(
4
) Only for the model DEGHBG90
(Note: Gas type sticker and data plate are attached to the underside of the base of the
appliance.)
CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)
REPLACING THE INJECTORS
The conversion procedure must be carried out only by an authorised person.
This appliance is suitable for use with Natural gas or Universal LPG (check the “gas type”
sticker attached to the appliance).
The nominal gas consumption and injector size details are provided in table above.
To replace the injectors proceed as follows:
Remove pan supports and burners from the cooktop.
Using a wrench, substitute the injectors “J” (gs. 5a, 5b, 5c, 5d) with those most
suitable for the kind of gas for which it is to be used (see table above).
A󰀩x to the appliance the warning label stating that the cooktop has been converted
for use with Natural gas/ULPG (supplied with the Natural gas/ULPG conversion kit).
A second Natural gas/ULPG conversion label should also be a󰀩xed to an adjacent
surface along with the duplicate data plate.
IMPORTANT
If the cooktop is suitable for use with Natural gas and must be converted for use with
Universal LPG, before connecting to gas main remove the appliance gas regulator
Loading ...