7
VALVE
PURGE POSITION
TO DRAIN
TO FOUNTAIN
FROM BASIN
The waterfall should be drained and cleaned every 3-4 months, possibly more depending on the quality of the water. The
waterfall surface can be cleaned using a warm soap and water mixture. Do not use harsh abrasive cleaners on the surface
of the stainless steel panel or it will permanently scratch the surface. Any wiping motion should be done in the direction of the
grain. If small scratches do occur, they can be blended out by gentle rubbing in the direc-
tion of the grain with a Scotchbrite pad.
The water should be completely flushed and drained from the system - switch the valve
to the purge setting, and run the pump to pump the water out. Refill the tank, run the water
through the fountain for 3 minutes and purge again. If calcium or hard water deposits are
forming on the panel or anywhere else in the system, cycle CLR solution through the
system until the deposits are removed then purge the system a few times with water.
If there are spots on the panel that dry out, check that there are no blocked ports in the manifold
tube. Remove the three nuts that secure the tube cover, and remove the cover. Remove the tube by
flexing it out in the centre. This will allow the ends to pull out. Poke the holes out with an opened
paper clip, and then flush the tube with water. Clean the angled surface that the manifold sprays
onto with liquid TSP (or TSP substitute). It is critical that this surface is extremely clean. Install the
tube back into the unit, with the ports aiming straight down and refill with water. Install the tube
cover and test the unit.
CLEANING AND MAINTENANCE
TUBE COVER
MANIFOLD TUBE
The sediment filter should be replaced every 3-4 months. To replace, unplug the pump. Lay a towel under the filter hous-
ing, as water will drain out of the housing when opening. Unscrew the housing, and remove the filter. Replace with a new
filter (part #N252-0001) available through your authorized NAPOLEON dealer. Push the new sediment filter firmly onto the
collar in the bottom of the housing. Screw the housing back onto the unit. This must be screwed on very tightly, or it will leak.
For cases where the unit is not hooked up to the water supply (for automatic refilling), it is still highly recommended that the
reservoir overflow be connected to a floor drain. This will prevent reservoir overflows, which can cause water damage to
surrounding materials. If the overflow is not connected to a floor drain, only refill or add water to the reservoir when the unit is
off. This will prevent the unit from over flowing.