PIPING DIAGRAM WITH UV-LIGHT
TO
ELECTRICAL
OUTLET
1
3
2
4
9 X
N570-0043 (8-32 X 3/4")
B
A
FROM WATERFALL
DRAIN TO BASIN
FROM THREE
WAY VALVE TO
WATERFALL
FROM BASIN TO
WATERFALL DRAIN
OVERFLOW
PROTECTION
PURGE LINE
FROM WATER
SOURCE TO
FLOAT VALVE
B
A
TO DRAIN
FROM THREE WAY
VALVE TO WATERFALL
SADDLE VALVE
FLOW CONTROL
VALVE / PURGE
VALVE
INSTALL THE SUPPLIED
HOSE CLAMPS ON EITHER
SIDE OF THE BASIN
SEDIMENT
FILTER
UV
LIGHT
Remove components from basin and assemble as shown. The fittings required are already attached to the filter and basin.
When using the optional UV light, the barbed elbow fitting on the “IN” side of the filter will need to be removed and threaded into the
elbow at the bottom of the UV light. Then connect the UV light directly to the sediment filter. Use teflon tape to seal these connec-
tions. Ensure that the supplied ground wire is connected from the grounding terminal on the UV light to either grounded copper
plumbing, or the ground in your electrical system. Use the supplied short piece of black tubing to run from the pump to the UV light.
Measure and cut the lines to the length necessary, push onto the barbed fittings and secure with the supplied hose clamps. Leak
test the waterfall before fully enclosing.