Kelvinator Gas Continuous Flow hot water system Remote controller and PCB error codes 19
Remote controller and PCB error codes
When remote controller is not installed When remote controller is installed
The error code will be displayed
on the remote controller.
123 45678
The LED on the PCB
will blink
The PCB is located at the bottom left-hand side of the
cabinet and the error codes can be read from the LED
on the PCB.
Error codes on the remote controller and PCB
LED on the PCB Error code on the controller Problem
LED light blinks once
031 Incorrect dipswitch setting
701 PCB or proportional valve fault
LED light blinks twice
311 Open or short circuit of hot water output thermistor
321 Open or short circuit of cold water inlet thermistor
391 Air-Fuel ratio rod disconnection or failure
LED light blinks three times
111 Ignition failure
121 Loss of ame
510 Main gas solenoid fault
511 Secondary gas solenoids fault
721 False flame detection
991 Imperfect combustion
LED light blinks four times 611 Irregular fan speed
LED light blinks ve times
101 Warning for 991 error code
741 Communication error with “main” controller
751
Communication error with “shower” or “ensuite”
controllers
To assist in the troubleshooting during installation or service the water heater has the added function of being able to
diagnose and report problems. In the rare event that a problem exists, the water heater will communicate the problem
via two methods, an error code on the remote controller or a blinking LED located on the PCB.
If an error code is displayed on the PCB or remote controller, contact the Electrolux service centre using the number
shown in the warranty section of this manual (page 23).