Before commissioning the gas continuous flow hot water
system, please conrm the following:
Installation location and clearances are correct
as per AS5601
Gas and water supply lines have been purged
of foreign matter
Correct gas type has been connected to the
water heater
There are no gas leaks on the gas pipework
and connections
A pressure limiting valve is installed (if water
supply pressure is above 1000kPa)
Hot and cold water connections are correct to
the water heater
A tempering valve has been installed (60°C
and 70°C preset model installations only)
Sufcient insulation has been installed on hot
water pipework
Water heater and pipework has been electrically
grounded
Power supply to the water heater is 240V AC 50Hz
Water heater is disconnected from the power
supply or unplugged
These steps are to be followed after the installation of the
gas continuous flow hot water system to ensure its safety
and performance. If the hot water system cannot be setup to
perform correctly as specied in this manual, please call the
service centre for further instructions (number located in the
warranty section of this manual).
caution
Before commissioning the hot water system first ensure
that the water heater is disconnected from the power
supply to protect it from being damaged due to air in
the system. Damage to the water heater due to improper
installation or commissioning may not be covered by the
Electrolux warranty.
gate or ball
valve on inlet
drain plug
lter
1. Remove, clean and replace the lter located on the
cold water inlet to the water heater (refer to page 11
of this manual).
lter
2. Open all the hot taps and xtures in the house.
3. Open the cold water isolation valve fully at the inlet to the
water heater
4. Check all pipe work for leaks and stop the leaks as
necessary
5. Once all the air has been forced out of the system and
water is owing freely from every hot tap or xture, close
all hot taps and xtures
6. Open the gas isolation valve fully by hand at the inlet to
the water heater
7. Check the gas pipe work for leaks and stop the leaks as
necessary
warning
If there is a gas leak that cannot be stopped, do not try to
start the water heater. Do not touch any electrical switches,
use a mobile phone or any other ignition source. Close the
main gas isolating valve to the premises and walk a safe
distance away. Call the gas supplier and follow the gas
supplier’s instructions.