Bora CKA2FIG Classic 2.0 Set Induction and Gas Cooktop with Integrated Ventilation System

User Manual - Page 34

For CKA2FIG.

PDF File Manual, 60 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
EN
34
Menu
www.bora.com
6 Menu
6.2 How to use the menu
Calling up the menu
i
The menu can only be called up if all cooking zones and
the cooktop extractor are inactive. In addition,
there must be no residual heat.
i
The menu button will only be displayed in the operating
panel when all functions are inactive and there is no
residual heat.
XX
Tap the menu button
XO
The menu is called up and the first menu item is displayed
(colour mode “beige”).
Closing the menu
XX
Long press on the menu button
XO
The menu is closed and the standard display appears.
Navigating the menu
XX
Tap or to go to the required menu item.
XO
If you have chosen a menu item, after 2 seconds the display
automatically changes to the set value.
Schematic diagram
i
As a help setting, the menu shows the number of optional
settings (1 – 3) for each menu item.
Fig. 6.1 Schematic diagram of the options
Confirming and saving menu settings
XX
Tap on or
or
XX
long press on the menu button
XO
The system automatically adopts and saves set values when
you move to another menu item or exit the menu.
i
Below you will find explanations on how to use the menu
and a description of all menu items that can be accessed
by the end customer.
i
Further menu items are available to distribution partners
and retailers (see Extended menu chapter).
6.1 Menu overview
i
The BORA Classic 2.0 system only shows the relevant/
applicable menu items according to the appliance
configuration.
Menu item/Description/Selection area Factory
setting
Menu:
1 Volume of the acoustic signals (10 – 100%) 80%
2 Childproofing feature (On/Off) Off
3 Automatic extractor control (On/Off) Off
4 Duration of the cleaning lock (5 – 30 s) 15 s
5 Duration of the automatic after-run function
(10 – 30 min)
20 min
6 Retrieving the software version
7 Retrieving the hardware version
8 System software update
9 Data export
A Show the recirculation filter service life
(only in recirculation mode)
B Show filter type, change filter type and
reset filter service life (only in recirculation
mode, when the filter service life < 20h)
H Extraction system configuration Recirculation
J Select the filter type
(only in the case of recirculation)
F1 (ULBF)
L Fan configuration 1
Extended menu (access code required):
B Show filter type, change filter type and
reset filter service life (only in the case of
recirculation)
D Demo mode Off
E Display and button test
F Reset to factory settings
Gas configuration menu (only on CKG):
P GPU (gas classification no.) 0
S GASt (gas characteristic curve) B
T GAS (turn off gas)
Tab. 6.1 Menu overview
Loading ...
Loading ...
Loading ...