INSTALLATION Before delivery
INSTALLATION
BEFORE DELIVERY
In order to be able to install your range or cooktop as soon as it is delivered, you must ensure that in your
kitchen, the gas and electrical supplies are ready for it.
1. SAFETY REQUIREMENTS
1.1. Ventilation
The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is
installed. It is essential that the kitchen where the ”La Cornuestove will be installed has excellent ven-
tilation to the outside, for vapor and combustion gases, and a fresh air inlet.
Do not use air recycling systems.
Ventilation exhaust devices can be vapor aspirators or hoods.
1.2. Clearances to combustible construction
The minimum horizontal distance from
sides of appliance to the adjacent vertical
combustible walls extending 18” (457 mm)
above the top panel is 12” (305 mm).
The maximum depth of overhead cabinets is
13” (330 mm).
The minimum horizontal distances between
overhead cabinets is not less then the
nominal width of the appliance (A).
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above
the surface units should be avoided.
Any element, either an extraction hood
or cabinet, situated directly above the
range must be made of non-
combustible material and placed at no
less than 30” (760 mm) above range.
The recommanded height is 36” (914
mm) above range.
1/2” recommended
1/2” recommended
Clearances to combustible construction
May be installed with zero clearance between adjacent combustible construction below the cooking surface
and the back and sides of the appliance.
We recommend to leave 1/2” gap on each side in order to allow enaugh space for moving the range.
To be used in conjonction with a suitable ventilation hood.
For cooktop installation ceramic cardboard with a minimum thickness of 20 mm must be installed under the