GAS
DRYER
INSTALLATION
REQUIREMENTS
Gas
Supply
AWARNING
Explosion
Hazard
Use
a
new
CSA
International
approved
gas
supply
line.
install
a
shut-off
valve.
Securely
tighten
all
gas
connections.
if
connected
to
LP,
have
a
qualified
person
make
sure
gas
pressure
does
not
exceed
13"
(330
mm)
water
column.
Examples
of
a
qualified
person
include:
licensed
heating
personnel,
authorized
gas
company
personnel,
and
authorized
service
personnel.
Failure
to
do
so
can
result
in
death,
explosion,
or
fire.
IMPORTANT:
Observe
all
governing
codes
and
ordinances.
This
installation
must
conform
with
all
local
codes
and
ordinances.
In
the
absence
of
local
codes,
installation
must
conform
with
American
National
Standard,
National
Fuel
Gas
Code
ANSI
2223.1/NFPA
54
or
CAN/CSA
B149.
A
copy
of
the
above
code
standards
can
be
obtained
from:
National
Fire
Protection
Association
One
Batterymarch
Park,
Quincy,
MA
02269
CSA
International
8501
East
Pleasant
Valley
Road
Cleveland,
Ohio
44131-5575
The
design
of
this
dryer
has
been
certified
by
CSA
International
for
use
at
altitudes
up
to
10,000
feet
(3048
m)
above
sea
level
at
the
B.T.U.
rating
indicated
on
the
model/serial
plate.
Burner
input
adjustments
are
not
required
when
the
dryer
is
operated
up
to
this
elevation.
When
installed
above
10,000
feet
(3048
m),
a
four
percent
(4%)
reduction
of
the
burner
B.T.U.
rating
shown
on
the
model/serial
plate
is
required
for
each
1,000
foot
(305
m)
increase
in
elevation.
For
assistance
when
converting
to
other
gas
types
and/or
installing
above
10,000
feet
(3048
m)
elevation,
contact
your
local
service
company.