10 English
Wall Venting
To make a 3½” x 10½” (8.9 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring
4.2
10” (1.1 cm) and 3
.7
10” (9.4 cm) down
from underside of cabinet and mark on the centerline on the back wall.
2. Mark lines 5¼” (13.3 cm) to the right and left of the centerline on the
wall.
3
7
10
(9.4 cm)
4.2
10
(1.1 cm)
5
1
/4
(13.3 cm)
5
1
/4
(13.3 cm)
Centerline
3. Use saber or keyhole saw to cut a rectangular opening in the wall for
the vent.
For 7" (17.8 cm) Round Vent System (Roof Venting)
To make a circular vent opening on the underside of the cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5” (12.8 cm) from the back wall on the underside of the top
of cabinet.
3. Use a compass or a circle template to draw a circle with a diameter of
7½” (19 cm).
4. Use saber or keyhole saw to cut the circular vent opening. Repeat
steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
*5”
(12.8 cm)
C
enterline
Drill Electrical Opening
1. Using a 1¼" (3 cm) drill bit, drill the hole in the dot marked previously
at the electrical strain relief.
Prepare Range Hood Vents
A
B
C
D
E
Install Strain Relief
1. Install a UL listed/CSA approved ½" (13 mm) strain relief (A).
For non-vented (Recirculating) Installations
Remove the (2) T10 Torx® screws and remove the top, front
rectangular vent cover (E). Go to "Electrical Connection" step.
For 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent Installations
For top vent installations, remove the top rectangular vent knockout
(C).
OR
For wall vent installations, remove the rear rectangular vent
knockout (B).
For 7" (17.8 cm) Round Vent Installations
Remove both top knockouts (C and D).
Attach Vent Damper or Transition
3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent Damper
1. Using (2) short Phillips head screws, install the 3¼" x 10" (8.3 x 25.4
cm) rectangular damper over the top or rear vent knockout removed in
previous step.
NOTE
If the wall cap used has a damper and it interferes with the rectangular
damper, remove the rectangular damper ap.
Installation Instructions
Installation Instructions
Loading ...
Loading ...