W415-1344 / A / 12.14.16
6
EN
2.4 GENERAL INFORMATION
4.12A
conformwithlocalcodes.Installationpracticesvaryfromregiontoregionanditisimportanttoknowthe
specificsthatapplytoyourarea,forexampleinMassachusettsState:
• Thisproductmustbeinstalledbyalicensedplumberorgasfitterwheninstalledwithinthecommonwealth
ofMassachusetts.
• Theappliancedampermustberemovedorweldedintheopenpositionpriortoinstallationofanappliance
insertorgaslog.
• Theapplianceoffvalvemustbea“T”handlegascock.
• Theflexibleconnectormustnotbelongerthan36inches(91.4cm).
• ACarbonMonoxidedetectorisrequiredinallroomscontaininggasfiredappliances.
• Theapplianceisnotapprovedforinstallationinabedroomorbathroomunlesstheunitisadirectvent
sealedcombustionproduct.
Theinstallationmustconformwithlocalcodesor,in
absenceoflocalcodes,theNationalGasandPropane
InstallationCodeCSAB149.1inCanada,ortheNational
FuelGasCode,ANSIZ223.1/NFPA54intheUnited
States.Suitableformobilehomeinstallationifinstalledin
accordancewiththecurrentstandardCAN/CSAZ240MH
Series,forgasequippedmobilehomes,inCanadaor
ANSIZ223.1andNFPA54intheUnitedStates.
Someapplianceshaveoptionalfansorblowers.Ifanoptionalfanorblowerisinstalled,thejunctionboxmust
beelectricallyconnectedandgroundedinaccordancewithlocalcodes,usethecurrentCSAC22.1Canadian
ElectricalCodeinCanadaortheANSI/NFPA70NationalElectricalcodeintheUnitedStates.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.nficertified.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
XIR4-1
NG P
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 40,000 40,000
Max. Output (BTU/HR) 33,200 33,200
Efficiency (w/the fan on) 83% 83%
A.F.U.E. (maximum value) 79% 79%
Min. Inlet Gas Supply Pressure 4.5" Water Column
(11mb)
11" Water Column
(27mb)
Max. Inlet Gas Supply Pressure 13" Water Column
(32mb)
13" Water Column
(32mb)
Manifold Pressure (Under Flow Conditions) 3.5" Water Column
(9mb)
10" Water Column
(25mb)
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating
up and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom
and bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance