8.5 BURNER REMOVAL
A. Remove the glass door, see "DOOR REMOVAL AND INSTALLATION" section. Remove the
logs, see "FINISHING" section.
8.6 FCM REPLACEMENT
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED.
!
WARNING
ACCESS PLATE
A. To access the fan control module, you must first pull out the appliance,
allowing enough room to access the left access plate.
B. Remove the screws holding the access plate in position.
C. Unplug the fan control module from the junction box. Unplug the night
light plug and blower plug (if applicable) from the fan control module.
D. Remove the 2 screws securing the fan control to the access plate and
replace. NOTE: Ensure ON/OFF switch is in the "ON" (-) position.
E. Reinstall the plugs and access plate
B. Remove the 8 screws that secure the log
support in place. Lift the support up and out.
Remove the 4 screws securing the cover
plate in place.
D. Remove the 2 screws that secure the bottom
burner cover in place and slide it out from
behind the rear manifold, then lift it up and
out of the appliance
C. Remove the 2 screws that secure the tube
burner in place and lift the burner up and out.
Then remove the two burner brackets, by
removing the 4 screws.
ON/OFF SWITCH
COVER PLATE
E. Remove the 4 screws holding the pan burner
in place and then lift it up and out of the
appliance.
LOG SUPPORT
BOTTOM BURNER COVER